[Bug 1001170] New: Correct Endianness of DHCP "Seconds Elapsed"field
- From: bugzilla-daemon at bugs dot ecos dot sourceware dot org
- To: unassigned at bugs dot ecos dot sourceware dot org
- Date: Wed, 9 Mar 2011 11:45:11 +0000
- Subject: [Bug 1001170] New: Correct Endianness of DHCP "Seconds Elapsed"field
- Auto-submitted: auto-generated
Please do not reply to this email. Use the web interface provided at:
http://bugs.ecos.sourceware.org/show_bug.cgi?id=1001170
Summary: Correct Endianness of DHCP "Seconds Elapsed" field
Product: eCos
Version: unknown
Platform: All
OS/Version: All
Status: UNCONFIRMED
Severity: normal
Priority: low
Component: Patches and contributions
AssignedTo: unassigned@bugs.ecos.sourceware.org
ReportedBy: kelvinl@users.sf.net
CC: ecos-patches@ecos.sourceware.org
Class: Advice Request
The bp_secs (Seconds Elapsed) field is not converted to network byte order,
resulting in badly ordered bytes depending on machine endianness.
--