(In reply to comment #9)
> Are you saying that all clocks are gated off by default until a driver gates
> its own clock on? That would make some sense because it would save power and
> most application writers would not have to be aware of it.
Allmost all are disabled. Check reset values of SIM_SCGCn registers in your
Kinetis reference manual for details.
The current eCos HAL enables ALL clocks and the new one will enable few,
leaving clockgating to device drivers.
--