This is the mail archive of the
ecos-discuss@sources.redhat.com
mailing list for the eCos project.
Re: goahead webserver do nothing
- To: ecos-discuss at sourceware dot cygnus dot com
- Subject: Re: [ECOS] goahead webserver do nothing
- From: Guillermo GARCIA <guga at teamlog dot fr>
- Date: Mon, 21 Aug 2000 16:10:19 +0200
- Organization: teamlog
- References: <XFMail.20000821050405.gthomas@redhat.com>
Gary Thomas a écrit :
> On 21-Aug-2000 Guillermo GARCIA wrote:
> > Hi there,
> >
> > I try to run the goahead webserver 2.1 on the edb7212 board.
> > i have installed 'ecos-1.3.1-1.i386.rpm' with the TCP/IP stack
> > 'net-1.0b1.epk'
> >
> > to do this i did the following steps.
> >
> > 1. mkdir ecos-work
> > 2. cd ecos-work
> > 3. ecosconfig new edb7xxx
> > 4. tclsh ecosadmin.tcl net-1.0b1.epk
> > 5. ecosconfig add CYGPKG_NET
> > 6. ecosconfig add CYGPKG_NET_ETH_DRIVERS
> > 7. ecosconfig add CYGPKG_NET_EDB7XXX_ETH_DRIVERS
> > 8. i have edited the ecos.ecc file to change some 'user_value'.
> >
>
> The most likely problem is that you need to expand the space reserved
> for malloc(). In the current version, memory for malloc() comes from
> a fixed size pool which is woefully too small for the GoAhead web
> server. Try making this additional configuration change:
>
> cdl_option CYGNUM_LIBC_MALLOC_MEMPOOL_SIZE {
> # Flavor: data
> # No user value, uncomment the following line to provide one.
> user_value 1638400
> # value_source default
> # Default value: 16384
> # Legal values: 32 to 0x7fffffff
> };
I have tried your solution and it work !!!
thanks a lot !
> Note: if you are using the command line 'ecosconfig', you can retrieve
> your changes via the "export" command. For example:
>
> % ecosconfig export config
> % cat config
> cdl_savefile_version 1;
> cdl_savefile_command cdl_savefile_version {};
> cdl_savefile_command cdl_savefile_command {};
> cdl_savefile_command cdl_configuration { description hardware template package };
> cdl_savefile_command cdl_package { value_source user_value wizard_value inferred_value };
> cdl_savefile_command cdl_component { value_source user_value wizard_value inferred_value };
> cdl_savefile_command cdl_option { value_source user_value wizard_value inferred_value };
> cdl_savefile_command cdl_interface { value_source user_value wizard_value inferred_value };
>
> cdl_configuration eCos {
> description "" ;
> hardware edb7212 ;
> template net ;
> package -hardware CYGPKG_HAL_ARM current ;
> package -hardware CYGPKG_HAL_ARM_EDB7XXX current ;
> package -hardware CYGPKG_DEVS_ETH_ARM_EDB7XXX current ;
> package -hardware CYGPKG_IO_SERIAL_ARM_EDB7XXX current ;
> package -template CYGPKG_HAL current ;
> package -template CYGPKG_IO current ;
> package -template CYGPKG_IO_SERIAL current ;
> package -template CYGPKG_INFRA current ;
> package -template CYGPKG_KERNEL current ;
> package -template CYGPKG_LIBC current ;
> package -template CYGPKG_LIBM current ;
> package -template CYGPKG_UITRON current ;
> package -template CYGPKG_IO_WATCHDOG current ;
> package -template CYGPKG_IO_WALLCLOCK current ;
> package -template CYGPKG_ERROR current ;
> package -template CYGPKG_NET current ;
> package -template CYGPKG_IO_ETH_DRIVERS current ;
> };
>
> cdl_option CYGHWR_HAL_ARM_EDB7XXX_VARIANT {
> user_value EP7212
> };
>
> cdl_option CYGNUM_LIBC_MALLOC_MEMPOOL_SIZE {
> user_value 1638400
> };
thanks for this information too, i'm a beginner with ecosconfig.
best regards,