--- Comment #62 from Ilija Kocho <ilijak@siva.com.mk> ---
Created attachment 2209
  --> http://bugs.ecos.sourceware.org/attachment.cgi?id=2209&action=edit
I2C driver Frequency divider table fix 130424 incremantal to att 2188

(In reply to comment #61)
> I remeasured the 400Khz numbers and then put the printed calcs in the table.
> 
> The 400Khz measurements were the same as before.
> 
> 
> Freq        Mode         Meas        Calc
> 100Khz      Std          98Khz       97Khz
> 100Khz      Agr          111Khz      111Khz
> 400Khz      Std          363Khz      390Khz
> 400Khz      Agr          416Khz      446Khz

It seems that there's discrepancy in I2C doc for frequency divider table. I did
some fixes to match your measurements. 400kHz Agr is pretty close to your scope
416666 Hz. Std is pretty close, but not so much 367647 Hz.